Formwork hydrostatic pressure
The pressure if concrete behaved as a liquid to the full pour height. Real design pressure is often lower.
Method
p = unit weight × height. Worked case: 25 kN/m³ over 3 m is 75 kN/m².
CIRIA C766 uses pour rate, temperature and concrete behaviour. This page does not. A temporary-works coordinator still has to design the form. See temporary works limit.
Last checked 2 October 2026. A scenario, not a design. See methodology, standards and the disclaimer.